Short answer

EU GMP Annex 1 is the European Commission's guideline for manufacturing sterile medicinal products. Its full 2022 revision, identical in substance to PIC/S Annex 1, applied from 25 August 2023, with clause 8.123 on lyophilizer sterilisation following on 25 August 2024. It centres on a site-wide contamination control strategy, risk management and barrier technology.

Key facts

  • Annex 1 was revised in full in 2022 (Commission document C(2022) 5938). It came into operation on 25 August 2023, except clause 8.123 on lyophilizer sterilisation and loading design, which applied from 25 August 2024.
  • The revised text was developed jointly by the EMA GMP/GDP Inspectors Working Group and PIC/S with the European Commission and WHO; PIC/S Annex 1 is identical apart from very minor editorial differences.
  • Clauses 2.3 and 2.5 require a site-wide contamination control strategy (CCS) that considers at least 16 listed elements, from premises and utilities to outsourced activities and continuous improvement.
  • For classification, Grade A allows 3,520 particles ≥0.5 µm per m³ at rest and in operation; Grade B allows 3,520 at rest and 352,000 in operation. Grade A and B areas must be requalified at least every 6 months.
  • Clause 8.87 requires pre-use post-sterilisation integrity testing (PUPSIT) of sterilising filters unless a documented risk assessment justifies an alternative, plus a non-destructive post-use test.
  • Annex 1 treats lyophilization as an extension of aseptic processing: Grade A transfer and loading, leak-rate checks at the start of every cycle, and sterilisation before each load for manually loaded dryers without barriers.

EU GMP Annex 1 is the rulebook for making sterile medicines in Europe, and since its 2022 revision it is also the shared text of the PIC/S inspectorates. Anyone sourcing sterile peptide vials, lyophilization or fill-finish for a European, PIC/S or WHO-aligned market is in practice buying against Annex 1. This guide explains what the annex is, when the revision applied, how it is organised, and what the clauses that matter most for peptide and biosimilar vials actually say.

Quotes and clause numbers below come from the published text, Commission document C(2022) 5938 [1]. For a process-level walk-through of filling, see aseptic fill finish explained.

What is EU GMP Annex 1?

Annex 1, “Manufacture of Sterile Medicinal Products”, is an annex to the EU Guidelines for Good Manufacturing Practice in EudraLex Volume 4 [1]. Its scope covers “a wide range of sterile product types (active substance, excipient, primary packaging material and finished dosage form)”, from single units to large batches and from manual to highly automated processes [1]. It applies quality risk management (QRM) to the whole document “to ensure that microbial, particulate and endotoxin/pyrogen contamination is prevented in the final product” [1].

Two framing statements in section 1 explain how inspectors read it. First, “where specific limits or frequencies or ranges are specified, these should be considered as a minimum requirement”, because they reflect “historical regulatory experience of issues that have been identified and have impacted the safety of patients” [1]. Second, principles such as the contamination control strategy, cleanroom classification and gowning may be applied voluntarily to non-sterile products where contamination control matters, but a manufacturer that does so must document which principles it applied [1].

EMA states that “any manufacturer of medicines intended for the EU market must comply with EU good manufacturing practice (GMP) no matter where in the world they are located” [2]. For sterile products, that means Annex 1.

When did the revised Annex 1 come into force?

MilestoneDateSource
Annex 1 first published (based on a PIC/S recommendation)1971[3]
Previous version in operation1 March 2009 (vial capping provisions 1 March 2010)[1]
PIC/S Annex 1 working group establishedMay 2014[3]
Revised Annex 1 issued by the CommissionDated 22 August 2022 (C(2022) 5938)[1]
Revised Annex 1 in operation (EU and PIC/S)25 August 2023[1] [4]
Clause 8.123 (lyophilizer loading design and sterilisation frequency) in operation25 August 2024[1] [4]

PIC/S describes the 2022 text as the first full revision, restructuring the annex and “introducing the principles of Quality Risk Management to allow for the inclusion of new technologies and innovative processes” [3]. The revision was “driven jointly by PIC/S and the EMA Inspectors’ Working Group (IWG) on GMDP in close co-operation with the European Commission (EC) and the World Health Organization (WHO)”, and PIC/S Annex 1 is identical to the EU text apart from “very minor editorial differences” [3]. It entered into force as part of the PIC/S GMP Guide PE 009-17; PIC/S revised the guide again as PE 009-18 in September 2026 to update Annex 19, not Annex 1 [4]. WHO’s sterile GMP text, published in 2022 as Annex 2 of Technical Report Series 1044, was revised “in collaboration with the European Union and the Pharmaceutical Inspection Co-operation Scheme (PIC/S)” [5].

The Commission gave its reasons in the document itself: to reflect “changes in regulatory and manufacturing environments”, to let manufacturers use “enhanced process understanding by using innovative tools as described in the ICH Q9 and Q10 guidelines”, and to “remove ambiguity and inconsistencies” while accounting for “advances in technologies” [1].

How Annex 1 is organised

The 59-page annex has 11 sections [1]:

SectionCovers
1. ScopeProduct types and use of the principles for non-sterile products
2. PrincipleKey areas, QRM and the contamination control strategy
3. Pharmaceutical quality systemSterile-specific PQS duties, including senior management oversight
4. PremisesCleanroom grades, barrier technology (RABS, isolators), qualification
5. EquipmentDesign and operation of equipment
6. UtilitiesWater, steam, gases and vacuum
7. PersonnelTraining, qualification and gowning by grade
8. Production and specific technologiesAseptic and terminal sterilisation, filtration, lyophilization, form-fill-seal, single-use systems
9. Environmental and process monitoringMonitoring limits, trending and aseptic process simulation
10. Quality controlMicrobiology expertise, bioburden, sterility testing
11. GlossaryDefinitions

The contamination control strategy (CCS)

The CCS is the core idea of the revision. Clause 2.3 says a CCS “should be implemented across the facility in order to define all critical control points and assess the effectiveness of all the controls (design, procedural, technical and organisational) and monitoring measures employed to manage risks to medicinal product quality and safety” [1]. The glossary defines it as “a planned set of controls for microorganisms, endotoxin/pyrogen and particles, derived from current product and process understanding” [1].

Clause 2.5 lists 16 elements a CCS should consider at minimum [1]:

  1. Design of plant and processes, with documentation
  2. Premises and equipment
  3. Personnel
  4. Utilities
  5. Raw material controls, including in-process controls
  6. Product containers and closures
  7. Vendor approval (key component suppliers, sterilisation of components and single-use systems, critical service providers)
  8. Management of outsourced activities and transfer of critical information between parties
  9. Process risk management
  10. Process validation
  11. Validation of sterilisation processes
  12. Preventive maintenance
  13. Cleaning and disinfection
  14. Monitoring systems, including the feasibility of alternative methods
  15. Prevention mechanisms: trend analysis, investigation, root cause and CAPA
  16. Continuous improvement

The CCS must be reviewed periodically and any change to the systems assessed for its impact “before and after implementation” (2.6) [1]. Clause 2.2 sets the order of priority: design first, then procedures, then monitoring, because “monitoring or testing alone does not give assurance of sterility” [1]. Clause 2.7 adds that “sole reliance for sterility or other quality aspects should not be placed on any terminal process or finished product test” [1]. Element 8 matters for anyone using contract fill-finish: the flow of critical information between sponsor and site is part of the site’s CCS.

Cleanroom grades and particle limits

Annex 1 keeps four grades (4.4). Grade A is “the critical zone for high-risk operations (e.g. aseptic processing line, filling zone, stopper bowl, open primary packaging or for making aseptic connections under the protection of first air)”. Grade B is the background for Grade A “where it is not an isolator”. Grades C and D handle less critical stages, act as isolator backgrounds, and can be used for “preparation/filling of terminally sterilised products” [1].

Table 1: total particles for classification

Grade≥0.5 µm/m³ at rest≥0.5 µm/m³ in operation≥5 µm/m³ at rest≥5 µm/m³ in operation
A3,5203,520Not specifiedNot specified
B3,520352,000Not specified2,930
C352,0003,520,0002,93029,300
D3,520,000Not predetermined29,300Not predetermined

Source: Annex 1 Table 1 [1]. Classification including 5 µm particles “may be considered where indicated by the CCS or historical trends” [1].

Table 5: total particles for routine monitoring

For monitoring (as opposed to classification), Table 5 adds 5 µm limits: 29 per m³ for Grade A at rest and in operation, 29 at rest and 2,930 in operation for Grade B [1]. Grade A must be monitored continuously for particles ≥0.5 and ≥5 µm “for the full duration of critical processing, including equipment assembly”, with a sample flow rate of at least 28 litres (1 ft³) per minute (9.16, 9.17) [1]. Occasional ≥5 µm counts in Grade A may be false counts, but “consecutive or regular counting of low levels may be indicative of a possible contamination event and should be investigated” [1].

Table 6: viable (microbial) action limits

GradeAir sample (CFU/m³)Settle plate, 90 mm (CFU/4 h)Contact plate, 55 mm (CFU/plate)Glove print, 5 fingers (CFU/glove)
ANo growthNo growthNo growthNo growth
B10555
C1005025Not applicable
D20010050Not applicable

Source: Annex 1 Table 6 [1]. The same air, settle plate and contact plate values apply during qualification (Table 2) [1].

Requalification of Grade A and B areas must happen at least every 6 months and of Grade C and D areas at least every 12 months (4.32) [1]. Unidirectional airflow should deliver a homogeneous air speed of 0.36–0.54 m/s (a guidance value) at the working position, “unless otherwise scientifically justified in the CCS” (4.30) [1].

Barrier technology: RABS and isolators

The 2022 text pushes barrier technology into the default. Clause 4.3 says RABS or isolators “are beneficial in assuring required conditions and minimizing microbial contamination associated with direct human interventions in the critical zone. Their use should be considered in the CCS. Any alternative approaches to the use of RABS or isolators should be justified” [1]. Clause 8.9 extends this to robotics and automation, citing “automated lyophilizer loading” as an example of eliminating direct human critical interventions [1].

The background required depends on the barrier: at least Grade B for RABS; generally at least Grade C for open isolators and at least Grade D for closed isolators, with the decision “based on risk assessment and justified in the CCS” (4.20) [1]. Isolator bio-decontamination “should be automated, validated and controlled within defined cycle parameters and should include a sporicidal agent” (4.22), and isolator glove integrity testing should generally happen “at a minimum frequency of the beginning and end of each batch or campaign” (4.21) [1]. Decontamination agents must be shown not to harm the product [1]; published work on vaporised hydrogen peroxide in an antibody filling isolator shows why, with protein oxidation observed above 100 ng/mL of hydrogen peroxide [6].

The reason for all this is the operator. A PDA analysis describes interventions as “a key source of microbiological contamination of sterile biopharmaceutical products, irrespective of the type of manufacturing system used” [7]. Annex 1 requires an authorised list of qualified interventions and full recording of each one in the batch record (8.16, 8.17) [1].

Sterile filtration and PUPSIT (clause 8.87)

If a product cannot be sterilised in its final container, Annex 1 requires filtration through a validated sterilising-grade filter “with a nominal pore size of a maximum of 0.22 µm” and aseptic filling into a previously sterilised container (8.79) [1]. The clause that drew most industry debate is 8.87: the sterilised filter assembly “should be verified by integrity testing before use (pre-use post sterilisation integrity test or PUPSIT)”, and a non-destructive post-use integrity test is required before the filter is removed from its housing [1].

Annex 1 accepts that “PUPSIT may not always be possible after sterilisation due to process constraints (e.g. the filtration of very small volumes of solution)”, and allows an alternative if “a thorough risk assessment has been performed” with controls covering filter sterilisation, the supply chain and product-specific risks of masking [1]. Laboratory data support the concern: with some clogging-prone fluids, post-use bubble point values rose enough to “camouflage a possible flaw in sterilizing filters” [8]. A 2025 PDA paper offers a risk framework for justifying alternatives, using the 2023 revision of ICH Q9 [9].

What Annex 1 says about lyophilization

For peptide and biosimilar vials, clauses 8.121 to 8.126 are the most relevant part of the annex [1].

ClauseRequirement (quoted or summarised from Annex 1)
8.121Lyophilization “is a critical process step”; everything that can affect sterility is an “extension of the aseptic processing” from filling to completion of the cycle
8.122Sterilisation of the lyophilizer, trays and vial support rings must be validated, and the hold time between sterilisation and use challenged in the APS; re-sterilise after maintenance or cleaning
8.123Design to minimise operator intervention; dryers “manually loaded or unloaded with no barrier technology separation should be sterilised before each load”; for automated or closed-barrier systems, frequency justified in the CCS (in operation from 25 August 2024)
8.124The vent filter is sterilised before each use and its integrity result forms part of batch release; “maximum permitted leakage of air into the lyophilizer should be specified and checked at the start of every cycle”
8.125Trays checked regularly for damage or distortion
8.126Loading pattern specified and documented; partially closed containers transferred “under grade A conditions at all times”; unsealed vials normally separated from operators by physical barriers; loading utensils sterile

Table 4 lists “loading of a lyophilizer” as a Grade A operation [1]. The aseptic process simulation for lyophilized products must cover “filling, transport, loading, a representative duration of the chamber dwell, unloading and sealing”, without actual freezing or boiling-over of the medium, and should replicate worst cases such as the longest loading time and the longest interval between lyophilizer sterilisation and use (9.33) [1]. The cycle science behind these controls is covered in our peptide lyophilization guide.

Aseptic process simulation, container closure and QC

Aseptic process simulation (section 9). Initial validation needs “at least three consecutive satisfactory simulation tests that cover all working shifts”; routine revalidation is normally “twice a year (approximately every six months) for each aseptic process, each filling line and each shift”; typically a minimum of 5,000 to 10,000 units are filled; and “the target should be zero growth” (9.38, 9.40, 9.46) [1]. Section 9 also states the simulation is not “the primary means to validate the aseptic process” (9.32) [1].

Container closure integrity. Containers closed by fusion with a volume of 100 ml or less need 100% integrity testing; vials sealed under vacuum must be tested for maintenance of vacuum before release and during shelf life; CCI validation must consider transport stresses; and “visual inspection is not considered as an acceptable integrity test method” (8.22, 8.24, 8.25) [1]. Annex 1 does not prescribe a method, and industry practice reflects that: a European white paper found “no gold standard for CCI test methods” [10].

Quality control (section 10). Bioburden must be tested on each batch of aseptically filled product, with limits set immediately before the final sterilising filter (10.3) [1]. Specifications should include microbial, particulate and endotoxin/pyrogen limits where monitoring or the CCS indicates a need (10.2) [1].

Annex 1 compared with FDA, WHO and India’s Schedule M

TopicEU GMP Annex 1 (2022)FDA aseptic guidance (2004)WHO TRS 1044 Annex 2 (2022)India revised Schedule M, Part II (2023)
Legal statusPart of EU GMP; applies to products for the EU market [1] [2]Non-binding guidance interpreting 21 CFR 210/211 [11] [12]WHO guideline, harmonised with EU/PIC/S [5]Binding rules under the Drugs Rules, 1945 [13]
Contamination control strategyRequired, site-wide (2.3) [1]Term not used [11]Required, same structure as Annex 1 [5]Term not used in Part II [13]
Grade A / critical zone, ≥0.5 µm/m³3,520 [1]Class 100 (ISO 5), 3,520 [11]3,520 [5]3,520 [13]
Grade A ≥5 µm limit for classificationNot specified [1]Not tabulatedNot specified [5]20 per m³ [13]
Filter integrity testingPUPSIT expected unless justified, plus post-use test (8.87) [1]Pre-use test “can be performed”; post-use test “should be routinely performed” [11]PUPSIT and post-use test (8.87) [5]Sterilised filter verified before use and confirmed immediately after use (6.11.2.7) [13]
Media fill frequencyAbout every 6 months per line and shift [1]Semi-annual per line [11]About every 6 months per line and shift [5]Media fills required for aseptic products [13]

India’s revised Schedule M (G.S.R. 922(E), 28 December 2023) states that sterility of aseptically processed products is assured “by ‘media simulation’ or ‘media fill’ runs”, and its Part II classification table still uses the earlier format with 5.0 µm limits of 20 per m³ for Grade A and 29 per m³ for Grade B at rest [13]. An Indian site that is compliant with Schedule M is therefore not automatically compliant with the 2022 Annex 1; a European buyer should check the site against Annex 1 itself.

What Annex 1 means for sterile peptide products

Most peptide medicines are parenteral, and EMA’s 2025 synthetic peptides guideline applies the general sterilisation decision trees to them. It accepts sterile filtration plus aseptic processing only if terminal sterilisation “under the least stressful conditions (achieving the required SAL ≤ 10-6) causes significant degradation” [14]. EMA’s sterilisation guideline gives the underlying reason: with aseptic processing, “accidental contamination caused by inadequate technique cannot be reliably eliminated by monitoring and control” [15]. Once aseptic processing is justified, Annex 1 governs how it is done, and for lyophilized peptides that includes the dryer.

A short checklist for a sterile peptide project:

  • Ask for the site’s CCS summary and how your product fits into it [1].
  • Confirm the barrier technology (isolator or RABS) and the background grade [1].
  • Review filter validation with your product and the PUPSIT position [1].
  • Review recent APS results for the line, container and shifts you will use [1].
  • For lyophilized products, review lyophilizer sterilisation frequency, leak-rate limits and the loading system [1].
  • Check the site’s EU GMP certificate status in EudraGMDP, the EU database of manufacturing authorisations and GMP certificates [16].

How Winhycare Pharma works with Annex 1 projects

Winhycare Pharma offers lyophilisation and vial filling of peptides and biosimilars at WHO-GMP certified manufacturing partners in India, with projects managed from Hyderabad, and clients may bring their own peptide. The partner’s process details and the documentation relevant to a project’s target market, including how the partner’s process compares with Annex 1 expectations, are shared per project. European clients can start with lyophilisation for Europe; see also peptide lyophilisation services, biosimilar lyophilisation, or send a lyophilisation enquiry.

Research peptides supplied by Winhycare Pharma are for laboratory research use only. Not for human or veterinary use.

Frequently asked questions

What is EU GMP Annex 1?+

Annex 1 is the part of the EU Guidelines for Good Manufacturing Practice (EudraLex Volume 4) that sets the specific requirements for manufacturing sterile medicinal products, including active substances, excipients and finished dosage forms. It covers premises, equipment, utilities, personnel, sterilisation and aseptic processing, monitoring, aseptic process simulation and quality control.

When did the revised Annex 1 come into force?+

The revised Annex 1 was published in August 2022 and came into operation on 25 August 2023. Clause 8.123, on lyophilizer design, loading and sterilisation frequency, came into operation one year later, on 25 August 2024. PIC/S applied its identical Annex 1 on the same dates.

What is a contamination control strategy under Annex 1?+

A contamination control strategy (CCS) is a planned set of controls for microorganisms, endotoxin/pyrogen and particles across the whole facility. Annex 1 clause 2.3 requires one to define all critical control points and assess the effectiveness of every design, procedural, technical and organisational control, and clause 2.5 lists at least 16 elements it must consider.

What are the cleanroom grades in Annex 1?+

There are four grades. Grade A is the critical zone for high-risk operations such as filling and stoppering. Grade B is the background for Grade A when an isolator is not used. Grades C and D are for less critical stages, isolator backgrounds and preparation or filling of terminally sterilised products.

Does Annex 1 apply to manufacturers outside the EU?+

Annex 1 applies to sterile medicinal products for the EU market. EMA states that any manufacturer of medicines intended for the EU market must comply with EU GMP no matter where in the world it is located. PIC/S member authorities apply the identical PIC/S Annex 1, and WHO's 2022 sterile GMP text was harmonised with it.

Is PUPSIT mandatory under Annex 1?+

Clause 8.87 expects PUPSIT for sterilising-grade filters, but recognises that it may not always be possible, for example with very small filtration volumes. An alternative is acceptable only after a thorough risk assessment and with controls that mitigate the risk of a non-integral filter. A non-destructive post-use integrity test is always expected.

What does Annex 1 say about lyophilization?+

Clauses 8.121 to 8.126 treat lyophilization as an extension of aseptic processing. They cover sterilisation of the lyophilizer and its hold time, design to minimise operator intervention, sterilisation before each load for manually loaded dryers without barrier technology, a leak-rate check at the start of every cycle, tray checks, and Grade A transfer and loading of partially stoppered vials.

How often must media fills be repeated under Annex 1?+

Initial validation needs at least three consecutive successful aseptic process simulations covering all shifts. After that, simulations are normally repeated twice a year, approximately every six months, for each aseptic process, filling line and shift. Each operator should take part in at least one successful simulation a year.

What is the difference between Annex 1 and FDA's aseptic processing guidance?+

Both share the same principles and ISO 5 / Grade A air quality for critical zones. FDA's 2004 guidance contains non-binding recommendations on meeting the US CGMP regulations; Annex 1 is the part of the EU GMP Guide that EU and PIC/S inspectors apply to sterile products. Annex 1 (2022) adds an explicit site-wide contamination control strategy, PUPSIT and stronger expectations for barrier technology.

Sources

  1. EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products, C(2022) 5938 final, European Commission
  2. Good manufacturing practice, European Medicines Agency
  3. Publication of revised PIC/S Annex 1 (September 2022), Pharmaceutical Inspection Co-operation Scheme (PIC/S)
  4. Entry into force of revised GMP Annex 1, PIC/S GMP Guide PE 009-17 (August 2023), Pharmaceutical Inspection Co-operation Scheme (PIC/S)
  5. WHO good manufacturing practices for sterile pharmaceutical products. WHO Technical Report Series No. 1044, Annex 2 (2022), World Health Organization
  6. Hubbard A, Roedl T, Hui A, et al. Vapor phase hydrogen peroxide decontamination or sanitization of an isolator for aseptic filling of monoclonal antibody drug product: hydrogen peroxide uptake and impact on protein quality. PDA J Pharm Sci Technol 2018;72:348–366, PDA Journal of Pharmaceutical Science and Technology (PubMed)
  7. Baseman H, Chakraborty S, Long MA, et al. Interventions risk evaluation and management in aseptic manufacturing. PDA J Pharm Sci Technol 2022;76:485–496, PDA Journal of Pharmaceutical Science and Technology (PubMed)
  8. Gupta VS, Jindal J, Gupta A, et al. Preuse/poststerilization integrity testing (PUPSIT): to do or not to do? PDA J Pharm Sci Technol 2020;74:301–308, PDA Journal of Pharmaceutical Science and Technology (PubMed)
  9. Waldron K, McFarland A, Baseman H, et al. A risk assessment and risk-based approach review of pre-use/post-sterilization integrity testing (PUPSIT). PDA J Pharm Sci Technol 2025;79:88–97, PDA Journal of Pharmaceutical Science and Technology (PubMed)
  10. Brown H, Mahler HC, Mellman J, et al. Container closure integrity testing: practical aspects and approaches in the pharmaceutical industry. PDA J Pharm Sci Technol 2017;71:147–162, PDA Journal of Pharmaceutical Science and Technology (PubMed)
  11. Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing, Current Good Manufacturing Practice (September 2004), US Food and Drug Administration
  12. 21 CFR 211.113: Control of microbiological contamination, Electronic Code of Federal Regulations
  13. Drugs (Amendment) Rules, 2023: revised Schedule M, G.S.R. 922(E), 28 December 2023, Central Drugs Standard Control Organisation, Government of India
  14. Guideline on the Development and Manufacture of Synthetic Peptides (EMA/CHMP/CVMP/QWP/367182/2025), European Medicines Agency
  15. Guideline on the sterilisation of the medicinal product, active substance, excipient and primary container (EMA/CHMP/CVMP/QWP/850374/2015), European Medicines Agency
  16. EudraGMDP database, European Medicines Agency

About the author

Kareem Ahmed Basha

Director & Chief Scientific Officer, Winhycare Pharma

Kareem Ahmed Basha is a director and the chief scientific officer of Winhycare Pharma in Hyderabad, India, and writes and reviews the division’s technical content on peptides, peptide APIs and lyophilisation.

He has nearly two decades of pharmaceutical quality experience, including 11 years 8 months at Dr. Reddy’s Laboratories in India and Mexico and earlier roles at Biocon and Anthem Biosciences.

  • Pharmaceutical quality assurance (cGMP, GLP)
  • Vendor qualification and CMO audits
  • Deviations, CAPA and change control
  • Data integrity and LIMS
  • Technology transfer
  • Peptide APIs
  • Peptide lyophilisation

Full profile · LinkedIn

Reviewed by Nisar Mohammed, Founder & Managing Director, on .

More from Winhycare Pharma · Peptide APIs

Products & services

WhatsApp Us Get a Quote