Blood bags stored on shelves inside a hospital blood bank refrigerator

4 ± 1°C control · 108L to 1008L · 4 models

Blood Bank Refrigerators (2–6°C)

WinHyCare designs and supplies blood bank refrigerators that hold whole blood and red cell units at 4 ± 1°C, inside the 2–6°C storage range. Four upright models run from 108L (66 bags of 450 ml) to 1008L, each with forced-air cooling, a 0.1°C-resolution display, a built-in temperature printer and a 72-hour battery that keeps the display and alarms running through power cuts. Prices are quoted per model; delivery, installation and service across India are coordinated from our Hyderabad service centre.

Get a blood bank refrigerator quote

Blood Bank Refrigerator Models, Capacity and Specifications

All four models share the same control system and alarm set. Choose by litres and bag count; open a model for dimensions and the full specification.

WinHyCare WBC-4V blood bank refrigerators compared by capacity, bag count, temperature control and backup.
Model CapacityBlood bags (450 ml)ControlCoolingBackup Price
WBC-4V108 4°c blood bank refrigerator WBC-4V108 108L664±1°CForced Air Cooling72 h battery (display + alarms) On request
WBC-4V208 4°c blood bank refrigerator WBC-4V208 208LAsk us4±1°CForced Air Cooling72 h battery (display + alarms) On request
WBC-4V658 4°c blood bank refrigerator WBC-4V658 658LAsk us4±1°CForced Air Cooling72 h battery (display + alarms) On request
WBC-4V1008 4°c blood bank refrigerator WBC-4V1008 1008LAsk us4±1°CForced Air Cooling72 h battery (display + alarms) On request
WBC-4V108 108L Blood Bank Refrigerator 4°C with 72-Hour Backup by WinHyCare 2°C to 6°C
4°C Blood Bank Refrigerator

WBC-4V108 108L Blood Bank Refrigerator 4°C with 72-Hour Backup

108L capacity. Compact blood bank refrigerator with five alarm functions, forced air cooling, and 72-hour backup battery.

View Details
WBC-4V208 208L Blood Bank Refrigerator 4°C with 72-Hour Backup by WinHyCare 2°C to 6°C
4°C Blood Bank Refrigerator

WBC-4V208 208L Blood Bank Refrigerator 4°C with 72-Hour Backup

208L capacity. 208L blood bank refrigerator with five alarm functions, forced air cooling, and 72-hour backup battery.

View Details
WBC-4V658 658L Blood Bank Refrigerator 4°C with 72-Hour Backup by WinHyCare 2°C to 6°C
4°C Blood Bank Refrigerator

WBC-4V658 658L Blood Bank Refrigerator 4°C with 72-Hour Backup

658L capacity. Large 658L blood bank refrigerator with five alarm functions, forced air cooling, and 72-hour backup battery.

View Details
WBC-4V1008 1008L Blood Bank Refrigerator 4°C with 72-Hour Backup by WinHyCare 2°C to 6°C
4°C Blood Bank Refrigerator

WBC-4V1008 1008L Blood Bank Refrigerator 4°C with 72-Hour Backup

1008L capacity. Largest blood bank refrigerator at 1008L.

View Details

Blood Bank Refrigerator Price in India

We do not publish a list price because the final figure depends on what you order. A quotation from us states:

  • the model and capacity (108L, 208L, 658L or 1008L) and the number of units;
  • delivery to your city and site;
  • installation and commissioning;
  • an optional annual maintenance contract after the warranty period.

Send capacity, quantity and delivery location and we reply with a model-wise quote. Request a price.

Alarms, Battery Backup and Temperature Records

Alarm conditions
High and low temperature, sensor error, power failure, door ajar and low battery, with an audible buzzer and flashing light.
Backup battery
72 hours for the display and alarms when mains power fails. Cooling needs mains or generator power.
Temperature records
Built-in printer for temperature records; 0.1°C display resolution.
Cooling
Microprocessor-controlled forced-air cooling with automatic defrost; R134a refrigerant.
Cabinet
Acrylic inner doors to limit cold loss between compartments, safety lock, interior light, castors.
Standards
Certified to ISO 9001/13485/14001 standards and designed to meet NABH/NBTC requirements.

Blood Bank Equipment We Supply

A blood centre needs separate storage for each component. These are the cold-chain items in our range; the regulatory equipment list is covered in our blood bank refrigerator requirements guide.

EquipmentTemperatureTypical use
Blood bank refrigerator2–6°C (4 ± 1°C control)Whole blood and red cell units
Platelet incubator with agitator20–24°C, oscillating shelvesPlatelet concentrates
Plasma freezer-10°C to -40°CFresh frozen plasma, cryoprecipitate
Ultra low temperature freezer-40°C to -86°CLong-term frozen components and samples
Blood transport box (powered cooler)2–8°C, -10 to -25°C or 22 ± 2°C modesTransfer between centres and hospitals

Tenders and Institutional Purchase

Government hospitals, state blood transfusion services and private blood centres can request a model-wise technical specification sheet for bid documents: capacity in litres and bags, temperature control, alarm conditions, battery backup, printer and power supply. We quote against your bill of quantities.

How we support tenders and procurement →

Delivery and Service Across India

We deliver blood bank refrigerators across India, including Mumbai, Delhi NCR, Bangalore, Hyderabad, Chennai, Pune, Kolkata and Ahmedabad and tier-2 cities such as Jaipur, Lucknow, Indore, Nagpur, Coimbatore, Visakhapatnam and Kochi. Installation and service are coordinated from our Hyderabad service centre. Delivery and installation details →

City pages: blood bank refrigerators in Mumbai, Delhi NCR, Bangalore and Kolkata.

Blood Bank Refrigerator FAQs

What temperature does a blood bank refrigerator maintain?

Blood bank refrigerators store whole blood and red cell units in the 2–6°C range. WinHyCare WBC-4V models control the cabinet at 4 ± 1°C with forced-air circulation, a 0.1°C-resolution display and high/low temperature alarms. Our guide on blood bank refrigerator requirements in India covers the regulatory basis.

How many blood bags does a 108L blood bank refrigerator hold?

The WBC-4V108 (108L) holds 66 blood bags of 450 ml. For the 208L, 658L and 1008L models, bag count depends on bag size and basket layout, so we confirm it with your quotation.

What is the price of a blood bank refrigerator?

Price depends on the model (108L to 1008L), quantity, delivery city and whether installation and an annual maintenance contract are included. We quote per model on request; send your capacity and delivery location through the contact form or WhatsApp.

What happens to stored blood during a power cut?

A 72-hour backup battery keeps the temperature display and alarms running when mains power fails, so staff are alerted and can monitor the cabinet. The compressor itself needs mains or generator power, so blood centres should connect the unit to backup power.

Can you supply blood bank refrigerators against tenders?

Yes. We provide model-wise technical specification sheets and quotations for tender and institutional purchases, covering capacity, temperature control, alarm conditions, battery backup and power requirements. See our tenders and procurement page for how we work with institutional buyers.

Who installs and services the refrigerators in India?

Delivery, installation and preventive maintenance are coordinated from our Hyderabad service centre for customers across India.

Need a blood bank refrigerator?

Send capacity, quantity and delivery city for a model-wise quote.

WhatsApp Us Get a Quote